Paraquat degradation by electrochemical oxidation in surface water: mathematical modeling

dc.audience.educationlevelPúblico en general/General publices_MX
dc.contributor.advisorLópez Zavala, Miguel Ángel
dc.contributor.authorValle Verduzco, Jorge Luis
dc.contributor.catalogerdnbsrpes_MX
dc.contributor.committeememberGarcía Orozco, Jorge Humberto
dc.contributor.committeememberMonárrez Cordero, Blanca Elizabeth
dc.contributor.departmentSchool of Engineering and Scienceses_MX
dc.contributor.institutionCampus Monterreyes_MX
dc.date.accepted2021-06-08
dc.date.accessioned2022-10-25T17:14:24Z
dc.date.available2022-10-25T17:14:24Z
dc.date.created2021-06-14
dc.date.issued2021-06
dc.descriptionhttps://orcid.org/0000-0002-5166-6983es_MX
dc.description.abstractToday’s society must face a series of challenges to ensure continuous survival. In addition, agriculture is one of the main activities in rural areas. In some cases, this is the only possible activity in the economy of these regions and, therefore, the only engine of growth. Pesticides are agents that protect crops from pests and diseases. Paraquat (1,1’-dimethyl-4,4’-bipyridinium dichloride) is a non-selective, contact broad- spectrum herbicide that has been widely used as an herbicide for decades. Paraquat poisoning has a high mortality rate. Several methods have been investigated to remove paraquat from aquatic environments. Currently, adsorption and degradation are the two main methods to remove/reduce paraquat. Solutions of paraquat dichloride tetrahydrate (100%, AccuStandard) were prepared with surface water (“Rodrigo Gomez” dam) with a concentration of 13 mg/L, 14 mg/L and 15 mg/L. Initial pH (8.2) of the solutions was adjusted to 3, 7 and 9. Then, electrochemical oxidation of samples of each solution was conducted at DC densities of 16.29 mA/cm2 (6.5 V), 30 mA/cm2 (12 V) and 60 mA/cm2 (24 V). The reaction times were 1, 2.5, 5, 7.5, 10, 15, 20, 25, 30, 35, 40, 50 and 60 minutes. Paraquat and their transformation products (TP) were analyzed by HPLC using an Agilent 1260 HPLC-DAD equipment (Agilent Technologies, Santa Clara, CA, USA) with a reverse phase Zorbax Eclipse XDB C-18 column with dimensions of 150 x 4.6 mm and 5 µm diameter spherical particles (Agilent Technologies, Santa Clara, CA, USA). All samples were filtered using 0.45µm polytetrafluoroethylene syringe filters before analysis. For the mathematical modeling of paraquat degradation, four scenarios were proposed. The first scenario was anodic oxidation with active electrodes with active hydroxyl radicals, the second scenario was with active chlorine species at pH < 3 with Cl2 (gas), the third scenario was with active chlorine species at 3 < pH < 8 with HClO as oxidant, and the fourth scenario was with active chlorine species at pH > 8 with ClO-. At pH 3 was the only treatment that completely degraded paraquat within 60 minutes since pH 7 and pH 9 did not show complete degradation of the herbicide. From the experiments carried out, the current density of 30 mA/cm2 at pH < 3 was the one that showed the best degradation. The validation of the mathematical model, at a current density of 30 mA/cm2, resulted in a correlation of 94% of paraquat degradation and 95% of Cl2 production (pH < 3). The formulation of ordinary differential equations facilitated the modeling.es_MX
dc.description.degreeMaster of Science in Engineering Scienceses_MX
dc.format.mediumTextoes_MX
dc.identificator7||33||3306es_MX
dc.identifier.citationValle Verduzco, J. (2021). Paraquat Degradation by Electrochemical Oxidation in Surface Water: Mathematical Modeling (master thesis). Tecnológico de Monterrey.es_MX
dc.identifier.cvu1001954es_MX
dc.identifier.orcidhttps://orcid.org/0000-0001-8846-8801es_MX
dc.identifier.urihttps://hdl.handle.net/11285/649777
dc.language.isoenges_MX
dc.publisherInstituto Tecnológico y de Estudios Superiores de Monterreyes_MX
dc.relationCONACyTes_MX
dc.relationTecnológico de Monterreyes_MX
dc.relation.isFormatOfpublishedVersiones_MX
dc.rightsopenAccesses_MX
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0es_MX
dc.subject.classificationINGENIERÍA Y TECNOLOGÍA::CIENCIAS TECNOLÓGICAS::INGENIERÍA Y TECNOLOGÍA ELÉCTRICASes_MX
dc.subject.keywordElectrochemical oxidationes_MX
dc.subject.keywordparaquates_MX
dc.subject.keywordanodic oxidationes_MX
dc.subject.keywordactive chlorine specieses_MX
dc.subject.keywordordinary differential equationses_MX
dc.subject.lcshTechnologyes_MX
dc.titleParaquat degradation by electrochemical oxidation in surface water: mathematical modelinges_MX
dc.typeTesis de maestría

Files

Original bundle

Now showing 1 - 4 of 4
Loading...
Thumbnail Image
Name:
Master Thesis Jorge Valle.pdf
Size:
1.07 MB
Format:
Adobe Portable Document Format
Description:
Tesis Maestría PDFA
Loading...
Thumbnail Image
Name:
Acuerdo de uso de obra tesis.pdf
Size:
496.97 KB
Format:
Adobe Portable Document Format
Description:
Carta de autorización
Loading...
Thumbnail Image
Name:
Autoría Jorge Valle.pdf
Size:
383.18 KB
Format:
Adobe Portable Document Format
Description:
Carta autoria
Loading...
Thumbnail Image
Name:
Firmas Jorge Valle.pdf
Size:
227.77 KB
Format:
Adobe Portable Document Format
Description:
Hoja de firmas

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.3 KB
Format:
Item-specific license agreed upon to submission
Description:
logo

El usuario tiene la obligación de utilizar los servicios y contenidos proporcionados por la Universidad, en particular, los impresos y recursos electrónicos, de conformidad con la legislación vigente y los principios de buena fe y en general usos aceptados, sin contravenir con su realización el orden público, especialmente, en el caso en que, para el adecuado desempeño de su actividad, necesita reproducir, distribuir, comunicar y/o poner a disposición, fragmentos de obras impresas o susceptibles de estar en formato analógico o digital, ya sea en soporte papel o electrónico. Ley 23/2006, de 7 de julio, por la que se modifica el texto revisado de la Ley de Propiedad Intelectual, aprobado

DSpace software copyright © 2002-2025

Licencia