Ciencias Exactas y Ciencias de la Salud

Permanent URI for this collectionhttps://hdl.handle.net/11285/551039

Pertenecen a esta colección Tesis y Trabajos de grado de las Maestrías correspondientes a las Escuelas de Ingeniería y Ciencias así como a Medicina y Ciencias de la Salud.

Browse

Search Results

Now showing 1 - 1 of 1
  • Tesis de maestría
    Assessment of reconstruction accuracy for under-sampled 31P-MRS data using compressed sensing and a low-rank Hankel matrix completion approach
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2024-12) García Quijano, Jossian Abimelec; Santos Díaz, Alejandro; emimmayorquin; Tamez Peña, José Gerardo; Montesinos Silva, Luis Arturo; Jiménes Ángeles, Luis; School of Engineering and Sciences; Campus Monterrey
    Phosphorus magnetic resonance spectroscopy and spectroscopic imaging (31P-MRS/MRSI) are techniques to evaluate energy metabolism in vivo, they are capable of measuring metabolites such as phosphocreatine and inorganic phosphate in muscle and brain tissue. Despite their capability, these techniques are not very often used in clinical settings due to the long acquisition times required. In recent years, compressed sensing has been widely used as an acceleration method for MRI signal acquisition and translated to MRS. In order to use it, one of the main criteria states that the aliasing resulting from the undersampling scheme must be incoherent, which is achieved using a pseudo-random sampling strategy. However, when a set of pseudo-random patterns are applied for the same acceleration factor, there is significant variability in the quality of the reconstructed signal. We present an evaluation of the influence of the under-sampling pattern in the quality of the signal reconstruction through a series of experiments in 31P-MRS data using the Low-rank Hankel matrix completion as the reconstruction method. Our results demonstrate that the reconstruction accuracy is heavily influenced by the selection of specific samples rather than the undersampling factor. Furthermore, the noise level in the signal has a more pronounced impact on reconstruction quality. Additionally, reconstruction accuracy is significantly correlated with the density of samples collected at early times, making it possible to set large time values to zero without producing any statistical difference for some cases.
En caso de no especificar algo distinto, estos materiales son compartidos bajo los siguientes términos: Atribución-No comercial-No derivadas CC BY-NC-ND http://www.creativecommons.mx/#licencias
logo

El usuario tiene la obligación de utilizar los servicios y contenidos proporcionados por la Universidad, en particular, los impresos y recursos electrónicos, de conformidad con la legislación vigente y los principios de buena fe y en general usos aceptados, sin contravenir con su realización el orden público, especialmente, en el caso en que, para el adecuado desempeño de su actividad, necesita reproducir, distribuir, comunicar y/o poner a disposición, fragmentos de obras impresas o susceptibles de estar en formato analógico o digital, ya sea en soporte papel o electrónico. Ley 23/2006, de 7 de julio, por la que se modifica el texto revisado de la Ley de Propiedad Intelectual, aprobado

DSpace software copyright © 2002-2025

Licencia