Ciencias Exactas y Ciencias de la Salud

Permanent URI for this collectionhttps://hdl.handle.net/11285/551039

Pertenecen a esta colección Tesis y Trabajos de grado de las Maestrías correspondientes a las Escuelas de Ingeniería y Ciencias así como a Medicina y Ciencias de la Salud.

Browse

Search Results

Now showing 1 - 10 of 16
  • Tesis de maestría
    Electrical-thermal characterization of a hybrid parabolic concentrator with spectral beam splitting
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2024-05-26) Garcia Ramos, Rafael Alejandro; Rivera Solorio, Carlos Iván; emipsanchez; Gijón Rivera, Miguel Ángel; Acosta Pazmiño, Iván Patricio; School of Engineering and Sciences; Campus Monterrey
    Electrical and thermal energy use has increased exponentially in recent years, mostly coming from intensive-use activities such as industrial and commercial areas. Also, typical energy (fossil fuels) to produce electricity and heat generates gases that are harmful to our planet, contributing to global warming. Solar energy is an excellent source of renewable energy and a solution to the mentioned problems. Photovoltaic-thermal (PVT) technologies allow to remove heat from PV cells, harnessing it as thermal energy and increasing electrical efficiency which usually decreases by 0.5%/°C over 25°C. Moreover, Low Concentrating PVT (LCPVT) collectors improve electrical and thermal power, reaching higher temperatures that can be used for industrial processes but preserving the integrity of the PV cells by keeping them below 100 °C. Many challenges arise from these collectors that, even when are well-studied, there are still gaps in commercial and scientific fields. LCPVT collectors lack a specific international standard for their characterization due to their hybrid nature, making the comparison and introduction to the market a complicated task. Furthermore, recently the application of the Spectral Beam Splitting (SBS) method has been the object of research. This method consists of dividing the sun’s electromagnetic spectrum into two parts, where the thermal part (ultraviolet and near infrared light) is reflected/absorbed by the filter, and the other part (visible light) is transmitted to the PV cells. The implementation of this method in LCPVT collectors is complex due to the geometry adjustments, being almost no experimental research on this field up to date. In this way, this work implements an LCPVT test bench, and its characterization is done by hybridizing the international standards ISO 9806 and IEC 62670-3. Also, its results are compared to numerical models and other collector geometries in the market. Moreover, an SBS filter liquid container was designed and preliminary tests applying liquids and solid in PV panels were done to check results in the electrical and thermal behavior of the panel. Lastly, the latter tests were taken as considerations for the design of an SBS filter applied to the LCPVT collector, and suggestions for future improvements were proposed. Such advances are useful for the scientific community by producing real values that support the validation of mathematical models and a better understanding of these technologies, thus being able to improve future designs.
  • Tesis de maestría / master thesis
    Evaluación técnica y económica del uso de tecnologías activas y pasivas para la reducción del consumo energético de un centro deportivo escolar
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2022-12-06) Valencia Solares, María Estrellita del Cielo; Rivera Solorio, Carlos Iván; puemcuervo, emimayorquin; Llamas Guillén, Sergio Ulises; Escuela de Ingeniería y Ciencias; Campus Monterrey; Gijón Rivera, Miguel Angel
    En el presente trabajo de tesis se realizó una simulación dinámica para evaluar el desempeño energético, económico y ambiental de una tecnología pasiva y dos tecnologías activas aplicadas en un centro deportivo escolar del Tec de Monterrey. En primera instancia, se seleccionó como estrategia pasiva un material de cambio de fase inorgánico (PCM, por sus siglas en inglés), y como estrategias activas paneles solares fotovoltaicos (FV) y colectores híbridos de canal parabólico de baja concentración (LCPVT). Estas tecnologías se modelaron en TRNSYS utilizando los types 1270, 103 y 50, respectivamente; además, para simular el comportamiento térmico del centro deportivo se usó el type 56. Se probaron tres escenarios diferentes para evaluar el desempeño de cada tecnología en el centro deportivo: en el Escenario 1 se integró el PCM en la envolvente de los techos externos del edifico, en el Escenario 2 se acopló un arreglo de paneles FV en la superficie de techo disponible del centro deportivo y en el Escenario 3 se simuló un sistema de colectores híbridos para bastecer la demanda térmica de la alberca y regaderas. Cabe mencionar que para el Escenario 2 y 3 también se modelaron los paneles FV y colectores híbridos junto con el PCM en los techos externos. Derivado del análisis realizado, se encontró que el Escenario 2 (paneles FV y PCM23) tuvo el mejor desempeño eléctrico, con el que se logra una reducción de 511 MWh al año (22% menos energía adicional consumida). Así mismo, es el que consigue una mayor cantidad de emisiones evitadas al ambiente de 234 ton CO2 eq al año. El Escenario 3 permite una reducción en el consumo de energía térmica de 546 MWh al año (32% menos de energía adicional consumida). Por otro lado, el escenario más rentable es el 2 (únicamente paneles FV), el periodo simple de recuperación es de 8.7 años y la TIR del proyecto es de 10.6%. El Escenario 1, que solo contempla el uso del PCM, no es económicamente factible, aunque se espera que el precio de éste disminuya en los próximos años; sin embargo, la ventaja de esta tecnología frente a las otras dos es que no requiere costos de operación y mantenimiento a lo largo de su vida útil. Es importante señalar que el PCM tiene diferente desempeño energético dependiendo de la época del año, y si bien se analizó el PCM que demostró mayores ahorros anuales, es necesario investigar el uso de combinaciones de este material con diferentes puntos de fusión para obtener mayores ahorros energéticos.
  • Tesis de maestría
    Estudio de la coción y enfriamiento de alimentos implementando nanofluidos en sistemas térmicos
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2021-12-06) Chadid Gutiérrez, Maria Alejandra; RIVERA SOLORIO, CARLOS IVAN; 121148; Rivera Solorio, Carlos Iván; puemcuervo, emipsanchez; Gijón Rivera, Miguel Ángel; López Salinas, José Luis; Escuela de Ingeniería y Ciencias; Campus Monterrey
    Los últimos descubrimientos en nanotecnología han permitido el desarrollo de partículas con tamaño menor a 100 nm, y con ello, el desarrollo de los nanofluidos. Los nanofluidos son la mezcla de un fluido base y partículas de tamaño menor a 100 nm o nanopartículas. Los nanofluidos han reportado gran potencial para aumentar la eficiencia energética de sistemas térmicos debido a la mejoría en las propiedades térmicas de los fluidos. En el presente trabajo se analiza el comportamiento de la transferencia de calor en dos equipos para el calentamiento y enfriamiento de alimentos comúnmente usados en la industria alimenticia: Vertical griddle y Maketable respectivamente. El vertical Griddle es un equipo que utiliza energía eléctrica para generar vapor que circula a través de una plancha en la cual se calientan hamburguesas y el Maketable o mesa para la preparación de alimentos es un equipo que mantiene frescos los alimentos en compartimientos inmersos en glicol refrigerado. Nanofluidos con base en agua y glicol fueron caracterizados para ser implementados en los respectivos equipos. Mediciones de conductividad térmica y calor específico fueron realizadas para nanofluidos de Al2O3, TiO2, MWCNTs y GNP, en concentraciones de 10\%, 6\% y 3.5\% y 3\% en peso. Los nanofluidos con las mejores propiedades térmicas fueron seleccionados para ser implementados en cada equipo según corresponda. Para al realización de los experimentos, prototipos del vertical griddle y Maketable fueron construidos e instrumentados. Mediciones de temperatura, presión y flujo másico fueron realizadas en los diferentes prototipos. El análisis de los datos obtenidos experimentalmente fue enfocado en la reducción de consumo de energía, remoción de calor, reducción porcentual de temperatura y reducción de constante de tiempo. Se pudo concluir que la implementación de nanofluidos de grafeno con base en agua con concentración en peso del 6\% en el vertical Griddle logró reducir el consumo de energía durante la marcha en un 30\% y de 4\% en total en comparación al consumo energético hallado para la prueba con agua. Además, se logró mantener la temperatura de las placas necesaria para la cocción del alimento obteniendo dichos ahorros en el consumo de energía. \\ Por otro lado, también se encontró que con la implementación de nanofluidos de Al2O3 con base en glicol al 20\% de concentración en peso en el Maketable, fue posible alcanzar mayores porcentajes de reducción de temperatura que los alcanzados con el fluido habitual de trabajo: glicol. Mientras que las reducciones de temperatura en el glicol fueron del 69\% al 75\%, las reducciones de temperatura alcanzada con el nanofluido de Al2O3 con base en glicol al 20\% de concentración van desde 73\% al 86\%. De la misma manera, la constante de tiempo encontrada para la prueba con nanofluido fue 20\% menor a la obtenida con glicol. Lo que implica que el 63\% del cambio de la temperatura se logró 20\% más rápido implementando nanofluido respecto al fluido base. Otros aspectos como la diferencia de presiones y remoción de calor fueron analizados para los equipos correspondientes. Por último, se proponen áreas de oportunidad para futuros estudios que puedan ser realizados en el vertical griddle y Maketable relacionados con la eficiencia energética de los equipos utilizando nanofluidos.
  • Tesis de maestría
    Integrated concentrating photovoltaic-thermal solar collector and membrane distillation system for desalination and vinasse treatment
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2021-11-17) Santana González, Juan Pablo; Rivera Solorio, Carlos Iván; puemcuervo; Gijón Rivera, Miguel Ángel; García Cuellar, Alejandro Javier; Escuela de ingeniería y Ciencias; Campus Monterrey
    This study presents the evaluation to integrate hybrid Concentrating Photovoltaic Thermal (CPVT) collectors with a Vacuum Membrane Distillation (VMD) module as a green alternative to produce freshwater. The CPVT collector provides the thermal and electrical energy required for the VMD to desalinate water. The performance of these integrated solar-assisted desalination technologies is numerically evaluated using TRNSYS. Parametric studies were conducted to find optimal operating conditions regarding the collector’s surface area and the brine’s set point temperature, from which a configuration using 4-collector units and a set point temperature of 55°C was chosen for a multi-city study. Annual weather conditions and specific information about the characteristics and operating conditions of a real CPVT collector and VMD module are considered in the dynamic simulation for 4 coastal cities: Acapulco, MX; La Paz, MX; Nadi, FJ; and Singapore, SG. The system can convert almost 50% of the solar radiation it receives into useful energy (8.2% into electricity and 41.4% into heat). The permeate production varied from 170.365 m3/m2_VMD in Singapore, SG, to 209.415 m3/m2_VMD in Acapulco, MX, showing a clear correlation between the solar radiation received and the performance of the system. Moreover, in a comparative study against a non-solar system, the specific energy cost for every m3 of freshwater produced could be decreased by 80% by implementing the CPVT collector. Additionally, an alternative application for this innovative system was tested, simulating the treatment of vinasses from the tequila production process. During the months with larger incident solar radiation, the performance of the system was optimal, with the peak specific permeate production achieved was 17.33 m3/m2_VMD during May, while the lowest SEC was 0.50 kWh/m3. The results of the simulations showed the exciting potential to use solar energy from hybrid CPVT collectors for a VMD process, not only for desalination in coastal cities but also as a viable technology to contribute to the production of freshwater demanded by industry and society.
  • Tesis de maestría
    Numerical investigation on the heat transfer enhancement by the combination of wavy tape, dimples and nanofluids in a PTC receiver.
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2021-09-10) Cuevas Iturbe, Luis Donaldo; RIVERA SOLORIO, CARLOS IVAN; 121148; Rivera Solorio, Carlos Iván; tolmquevedo; Bretado de los Ríos, Mariana Soledad; Morales Menéndez, Rubén; School of Engineering and Sciences; Campus Monterrey; Gijón Rivera, Miguel Ángel
    Parabolic trough collector (PTC) is the most developed concentrating solar technology. It represents a viable way to substitute fossil fuels in the production of heat process, however higher thermo-hydraulic performance is needed to be more competitive. This study presents a numerical investigation of dimples, wavy tape and nanofluids (Al2O3, TiO2 and Al2O3-TiO2 dispersed in water at 4% concentration) in combination, in a PTC receiver. Fluent was used to solve the fluid dynamics and heat transfer characteristics inside the PTC receiver with the different heat transfer enhancement techniques for Reynolds numbers ranging from 1.48x104 to 1.77x105. The study showed that dimples with Al2O3/water nanofluid lead to a higher thermo-hydraulic performance evaluated with the Thermal Performance Index with values as high as 1.78. It was also proven that the highest thermal enhancement is obtained when the three heat transfer augmentation techniques are used in combination (wavy tape, dimples, and Al2O3/water nanofluid) with a heat transfer coefficient enhancement of 3.12 times that of a plain PTC receiver with no thermal enhancement. Nonetheless, the combination of techniques also come with a high cost of pressure drop increase from 8.52 to 12.59 compared to the plain PTC receiver. The combination of all the techniques proved more useful at low Reynolds numbers because the flow is not as turbulent. As Reynolds number increases, the thermal increase is not proportional to the mean pressure drop increase, then leading poor performances at high Reynolds numbers. On the other hand, wavy tape with nanofluids proved to have better thermal performances at high Reynolds numbers. The use of nanofluids always leads to the higher thermal performance values. Regarding the different nanofluids, the difference among them is non-significant compared to each other in terms of mean pressure drop, however in terms of heat transfer coefficient improvement, there is about 1.34% difference between the highest thermal performance nanofluids (Al2O3, and Al2O3-TiO2) and TiO2/water nanofluid.
  • Tesis de maestría
    Passive cooling strategies and performance of low energy residential buildings in semi-arid climate conditions
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2021-06-15) Mousavi, SeyedehNiloufar; RIVERA SOLORIO, CARLOS IVAN; 121148; Rivera Solorio, Carlos Iván; hermlugo, emipsanchez; Lopez Salinas, Jose Luis; School of Engineering and Sciences; Campus Monterrey; Gijón Rivera, Miguel Ángel
    This numerical study compares annual energy consumption of three building prototypes under semi-arid climate conditions of Monterrey. These common cases were selected based on Mexican housing classification of houses including, one story house, apartment of 4 story house, double story house, named C1, C2, and C3, which were simulated using DesignBuilder software. Based on literature reviews and availability of materials, 6 scenarios were defined for walls component, similarly 6 scenarios for the roof of all cases with the application of phase change material (PCM), reflective paint, and insulation. Regarding the opening envelope of cases 5 scenarios were defined including the application of double clear glazing, double low-e glazing, and reflective glazing coupled with shading. Selection factor to find the most efficient combination were based on annual energy and material cost of scenarios against each other and base case. Firstly, for wall component of envelope results showed that PCM with insulation (PI) outperformed other scenarios for all cases however with regards to its cost reflective paint with insulation (Ir) was more efficient, similar pattern was found for roof component for all cases where Ir scenario outperformed in term of cost and energy. Secondly, with regards to the opening scenarios loE double glazing coupled with horizontal shading outperformed others, consequently three selected scenarios were combined for all cases and formed the energy efficient configuration (EEC) to analyze the improvement in indoor thermal comfort, thermal improvement, carbon emission reduction, and economic benefit of their application. Various actions are carried out to perform these analyses; calibration of the model with experimental data and comparative ASHRAE benchmark case study 600FF, climate data simulations with TRNSYS software, and sensitivity analysis for PCM selection. Also, it was found that PCM was effective strategy if the thickness of material increases to similar thickness as insulation it could save up to 57% of energy for C1 which is the highest saving rate as compared to all other scenarios, however due to its high cost it is not economically efficient in local context. The results demonstrate that EEC cases achieved total annual energy saving of around 53%, 55%, and 58% for C1, C2, and C3 cases, furthermore, concerning the thermal comfort improvement were around 45%, 33%, and 38% respectively. With regards to thermal performance during hottest day temperature, improvement was observed with averages of 5.9°C and 3.2°C for C1 and C3 whereas C2 had no improvement during this period, however during coldest day all cases had an average improvement of 2.4°C, 2°C, and 2.6°C. Concerning the Carbon footprints, reduction of emission for each case of C1, C2 and C3 were around 1578 Kg, 2798 Kg, and 3004 Kg annually, with 6 years, period of return for C1 and almost 3.5 years for C2 and C3. To conclude, the scenarios studied could be integrated with renewable sources of energy supply such as PV panels and result in net-zero building envelope, as all cases almost saved more than 50% of energy.
  • Tesis de maestría
    Modelación del comportamiento térmico y extracción de energía de un estanque solar con inversor de flujo helicoidal y nano fluidos
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2021) Villanueva Boone, Fernando; RIVERA SOLORIO, CARLOS IVAN; 121148; Rivera Solorio, Carlos Iván; tolmquevedo, emipsanchez; Gijón Rivera, Miguel Angel; García Cuellar, Alejandro Javier; Escuela de Ingeniería y Ciencias; Campus Monterrey
    Se realizó un modelo matemático para estudiar el comportamiento de un estanque solar. Se estudió la transferencia de calor dentro del estanque, así como la extracción de calor con un inversor de flujo helicoidal instalado en el fondo del estanque. Se tomaron las condiciones ambientales locales, como la velocidad del viento, humedad, radiación incidente y temperatura ambiente, para correr la simulación del modelo. El estanque fue dividido en 3 zonas. Se calcularon las ganancias y pérdidas de calor por absorción de la radiación, pérdidas por convección, evaporación, radiación, por las paredes y el suelo, utilizando diferentes modelos y correlaciones. Además, se añadió al modelo la extracción de calor con el uso de nano fluidos, por lo que se usaron correlaciones para calcular sus propiedades. Se resolvió el modelo discretizando las ecuaciones diferenciales y resolviendo para la temperatura del siguiente nodo temporal. El modelo arroja las temperaturas del estanque para diferentes alturas cada 10 minutos, así como la temperatura de salida del intercambiador de calor y el calor extraído. Para validar el modelo, se compararon los datos de la simulación con los datos experimentales de 2 estanques previamente construidos y se construyó uno nuevo de 5 m3. Se instaló un CFI de 8 metros en la zona convectiva inferior y se corrieron 3 pruebas totales, una con agua y las otras dos con el nano fluido Al2O3/agua a 2% y 3% en volumen. Por último, se compararon los datos experimentales y los de la simulación, y se hizo una comparación de la extracción con agua y con nano fluidos.
  • Tesis de maestría
    Numerical Analysis of Heat and Mass Transfer in Emerging Technologies of Cooling Systems
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2020-06-15) Mitz Hernández, Enrique; MITZ HERNANDEZ, ENRIQUE; 881783; Rivera Solorio, Carlos Iván; ilquio, emipsanchez; Huertas Cardozo, José Ignacio; School of Engineering and Sciences; Campus Monterrey; Gijón Rivera, Miguel Angel
    We numerically analyze two distinct technologies for air cooling systems: (1) Dew-Point Evaporative Cooling (DPEC) Systems, and (2) Nanofluids in Helical Coils Heat Exchangers (HCHE). For the first technology, we developed a 1D model with thermophysical properties dependent on the temperature, humidity ratio and atmospheric pressure. The model was evaluated under different conditions in a parametric analysis. Then, a regression maintaining the same atmospheric pressure and channel length was found for the DPEC model. The regression shows a good fit with modeled data, having a RMSE of 1.4 and R2adj of 93%. Also, the model was evaluated in 4 climates (Very arid, arid, warm, and mild). On the other hand, the Nanofluids in HCHE model was implemented in the commercial software Fluent. The optimal mesh consists of 3.529 Million of elements using a structured mesh. The model implemented was set in a turbulent regime, with thermophysical properties dependent on temperature and constant wall temperature and uniforms inlet velocity and temperature. The thermophysical properties for the nanofluids were set from thermophysical properties dependent on the temperature of the base fluid and constant thermophysical properties of the nanoparticle. Then, a case analysis varying the geometry, Dean number, nanofluid (base fluid and nanoparticle) and nanoparticle volume concentration was developed. Finally, from the data modeled we found a correlation for Nusselt number of the Water / Alumina nanofluid.
  • Tesis de maestría
    Study of heat transfer in tubular-panel and spray cooling systems applied to the electric arc furnace walls
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2018-05-15) Contreras-Serna, Josué; Rivera Solorio, Carlos Iván; García Cuéllar, Alejandro Javier; López Salinas, José Luis
    This project consists in a heat transfer study in the electric arc furnace (EAF) walls, focused in the tubular-panel and spray cooling systems for the EAF located at Ternium-Guerrero plant, in the northeastern region of Mexico. The tubular-panel system is the one currently used to keep the walls cooled, composed of a total of 14 tubular panels. More dangerous accidents in the EAF operation, are the water steam explosions, which occur due to water leaks in the piping system inside the furnace. Spray cooling is given from the outside of the EAF, reducing the possibility of water directly impacting molten steel. The main purpose of this research is to know the operational conditions of both systems, verifying if the spray cooling system could be as good as the tubular system for the removal of heat on walls, efficiency and keeping the walls at low temperatures. The following procedures were used to estimate the water flow distribution in the cooling systems and the heat transfer in the walls. Piping network configurations are proposed for both systems. Models that consider surface-energy balances between different layers of the EAF’s walls and the heat radiated onto the walls by the electric arc and the molten-slag surface are developed herein. Conventional correlations were used for determining the heat transfer coefficients inside the tubular panels (Internal convection) and alternate correlations for determining the heat transfer coefficients for the external convection (spray cooling). Additional scenarios were done trying to improve the operational conditions and heat removal of each system. Water flow regulation by valves in each panel in tubular system and jet nozzles are used instead of spray nozzles in the spray system to verify the effectiveness of the spray cooling. The study was conducted via a parametric analysis in which the principal factors governing the process—the arc coverage and slag-layer thickness adhering to the walls—were varied. The results of the tubular-panel system were compared with experimental measurements of the outlet water temperature in each panel, showing a good approximation; allowing us to predict the operational conditions of the furnace. For both systems the optimal operating condition of the EAF, is when the arc is completely covered and the maximal thickness of the slag-layer that can be reached is around to 4.5 cm, it does that energy losses to decrease significantly and to keep walls at low temperatures. The minimal temperature difference between the inlet and final flow is around to 3 K. The spray cooling system operates with a lower heat removal capacity and pressure than the tubular-panel, causing that inner wall surface temperature to be approximately 20 degrees higher than when using the tubular system for critical operating conditions. Under optimal operating conditions each nozzle removes approximately 8.5 kW of thermal power. It is concluded that each cooling system has different temperatures and heat-removal capacity, which are highly dependent on the water flow within them. It is proved that slag-layer thickness and arc-coverage factors significantly affect the safe operation of the EAF, as well as its energy efficiency. This is a semi-analytical study; the equations of models were obtained analytically, and an equation-solver program is necessary to treat the non-linear equations obtained. Relatively few computational resources are required for this method.
  • Tesis de maestría
    Determinación de CLTD para cargas de enfriamiento de edificaciones ubicadas en ciudades de clima cálido en México
    (2017-05-20) Vallejo Coral, Evelyn Catalina; Rivera Solorio, Carlos Iván; Gijón Rivera, Miguel Angel; López Salinas, José Luis
    En México, el mayor consumo de energía eléctrica se presenta en las épocas de verano debido al uso de sistemas de acondicionamiento de aire. Debido a esto, el mayor porcentaje de viviendas que cuentan con equipos de aire acondicionado se encuentra en las zonas climáticas con mayores temperaturas ambientales. La estimación, más precisa, de las cargas de enfriamiento para el dimensionamiento de equipos representa un área de oportunidad para disminuir el consumo de energía eléctrica debido a que, aproximadamente, la mitad del territorio mexicano se encuentra en zonas climáticas en las cuales, más del 30% de las viviendas cuentas con sistemas o equipos de aire acondicionado. El método CLTD/SCL/CLF es un procedimiento de un solo paso para la estimación de cargas térmicas de enfriamiento a causa de calor ganado a través de paredes expuestas al sol y a través de techos. El método considera la naturaleza transitoria del fenómeno de transferencia de calor y la inercia térmica de los elementos. El objetivo principal del este proyecto fue determinar los valores CLTD para techos planos y paredes a partir de la temperatura en la superficie interna, la cual se obtuvo mediante la solución del modelo matemático que considera la transferencia de calor en estado transitorio a través de los elementos de la envolvente. Un algoritmo computacional fue desarrollado para obtener la solución de modelo matemático, que representa el fenómeno analizado, mediante la técnica de la transformada finita compleja de Fourier (CFFT). Para validar la temperatura interna calculada con el algoritmo se obtuvieron datos experimentales acerca del comportamiento térmico de una pared de bloque orientada hacia el oeste y un techo de concreto que forman parte de un espacio climatizado en la Casa Solar, ubicada en el campus del ITESM en Monterrey. Los valores de CLTD, para una edificación en Turquía, reportados por Adil & Yumrutas (2015), se consideraron como caso de referencia para comparar con los resultados obtenidos mediante el algoritmo considerando los parámetros térmicos de referencia. Los factores CLTD del techo presentaron correspondencia cualitativa y cuantitativa a los valores reportados y para la pared se observó únicamente correspondencia cualitativa debido a que, existe incertidumbre en varios datos de entrada. Para conocer las ventajas acerca de la aplicación de CLTD determinados en base a condiciones térmicas locales, se aplicó los factores de corrección establecidos por ASHRAE para Monterrey en dos casos de estudio (pared N°3 y techo N°13, codificación ASHRAE). Se observó que, los CLTD calculados mediante el algoritmo desarrollado son menores a los definidos por ASHRAE para Monterrey. Se seleccionaron tres materiales resistentes para paredes (ladrillo, bloque de concreto y bloque de ladrillo) y tres materiales para techos (concreto, bovedilla de poliestireno expandido y poliestireno extruido) en base a los cuales se establecieron 6 casos de estudio para determinar los factores CLTD en Monterrey, Veracruz y Mexicali. Se observó que, el bloque de adobe es el material aislante más recomendado para la construcción de paredes y que la vigueta con bovedilla de poliestireno expandido es la mejor configuración de techo para disminuir el calor transferido hacia el interior, en comparación a los techos de vigueta con bovedilla de concreto o losa maciza de concreto. Finalmente se concluyó que, la utilización factores CLTD que no consideran las condiciones locales pueden sobredimensionar la carga de enfriamiento requerida en un sistema de acondicionamiento de aire
En caso de no especificar algo distinto, estos materiales son compartidos bajo los siguientes términos: Atribución-No comercial-No derivadas CC BY-NC-ND http://www.creativecommons.mx/#licencias
logo

El usuario tiene la obligación de utilizar los servicios y contenidos proporcionados por la Universidad, en particular, los impresos y recursos electrónicos, de conformidad con la legislación vigente y los principios de buena fe y en general usos aceptados, sin contravenir con su realización el orden público, especialmente, en el caso en que, para el adecuado desempeño de su actividad, necesita reproducir, distribuir, comunicar y/o poner a disposición, fragmentos de obras impresas o susceptibles de estar en formato analógico o digital, ya sea en soporte papel o electrónico. Ley 23/2006, de 7 de julio, por la que se modifica el texto revisado de la Ley de Propiedad Intelectual, aprobado

DSpace software copyright © 2002-2026

Licencia