Ciencias Exactas y Ciencias de la Salud

Permanent URI for this collectionhttps://hdl.handle.net/11285/551039

Pertenecen a esta colección Tesis y Trabajos de grado de las Maestrías correspondientes a las Escuelas de Ingeniería y Ciencias así como a Medicina y Ciencias de la Salud.

Browse

Search Results

Now showing 1 - 1 of 1
  • Tesis de maestría
    Paraquat degradation by electrochemical oxidation in surface water: mathematical modeling
    (Instituto Tecnológico y de Estudios Superiores de Monterrey, 2021-06) Valle Verduzco, Jorge Luis; López Zavala, Miguel Ángel; dnbsrp; García Orozco, Jorge Humberto; Monárrez Cordero, Blanca Elizabeth; School of Engineering and Sciences; Campus Monterrey
    Today’s society must face a series of challenges to ensure continuous survival. In addition, agriculture is one of the main activities in rural areas. In some cases, this is the only possible activity in the economy of these regions and, therefore, the only engine of growth. Pesticides are agents that protect crops from pests and diseases. Paraquat (1,1’-dimethyl-4,4’-bipyridinium dichloride) is a non-selective, contact broad- spectrum herbicide that has been widely used as an herbicide for decades. Paraquat poisoning has a high mortality rate. Several methods have been investigated to remove paraquat from aquatic environments. Currently, adsorption and degradation are the two main methods to remove/reduce paraquat. Solutions of paraquat dichloride tetrahydrate (100%, AccuStandard) were prepared with surface water (“Rodrigo Gomez” dam) with a concentration of 13 mg/L, 14 mg/L and 15 mg/L. Initial pH (8.2) of the solutions was adjusted to 3, 7 and 9. Then, electrochemical oxidation of samples of each solution was conducted at DC densities of 16.29 mA/cm2 (6.5 V), 30 mA/cm2 (12 V) and 60 mA/cm2 (24 V). The reaction times were 1, 2.5, 5, 7.5, 10, 15, 20, 25, 30, 35, 40, 50 and 60 minutes. Paraquat and their transformation products (TP) were analyzed by HPLC using an Agilent 1260 HPLC-DAD equipment (Agilent Technologies, Santa Clara, CA, USA) with a reverse phase Zorbax Eclipse XDB C-18 column with dimensions of 150 x 4.6 mm and 5 µm diameter spherical particles (Agilent Technologies, Santa Clara, CA, USA). All samples were filtered using 0.45µm polytetrafluoroethylene syringe filters before analysis. For the mathematical modeling of paraquat degradation, four scenarios were proposed. The first scenario was anodic oxidation with active electrodes with active hydroxyl radicals, the second scenario was with active chlorine species at pH < 3 with Cl2 (gas), the third scenario was with active chlorine species at 3 < pH < 8 with HClO as oxidant, and the fourth scenario was with active chlorine species at pH > 8 with ClO-. At pH 3 was the only treatment that completely degraded paraquat within 60 minutes since pH 7 and pH 9 did not show complete degradation of the herbicide. From the experiments carried out, the current density of 30 mA/cm2 at pH < 3 was the one that showed the best degradation. The validation of the mathematical model, at a current density of 30 mA/cm2, resulted in a correlation of 94% of paraquat degradation and 95% of Cl2 production (pH < 3). The formulation of ordinary differential equations facilitated the modeling.
En caso de no especificar algo distinto, estos materiales son compartidos bajo los siguientes términos: Atribución-No comercial-No derivadas CC BY-NC-ND http://www.creativecommons.mx/#licencias
logo

El usuario tiene la obligación de utilizar los servicios y contenidos proporcionados por la Universidad, en particular, los impresos y recursos electrónicos, de conformidad con la legislación vigente y los principios de buena fe y en general usos aceptados, sin contravenir con su realización el orden público, especialmente, en el caso en que, para el adecuado desempeño de su actividad, necesita reproducir, distribuir, comunicar y/o poner a disposición, fragmentos de obras impresas o susceptibles de estar en formato analógico o digital, ya sea en soporte papel o electrónico. Ley 23/2006, de 7 de julio, por la que se modifica el texto revisado de la Ley de Propiedad Intelectual, aprobado

DSpace software copyright © 2002-2025

Licencia